CBL Series Universal Central Battery System

Brand: Signtex Lighting


See PRODUCT DESCRIPTION below

Starting at $1,776.93

Variation Options Filter (38 Model Variations to choose) Use these filters to narrow Product Variations list below.
As configured: CBL

All (*) form fields are required.

RESET

PRODUCT VARIATIONS


(Use the filters above to narrow or change this selection.)

$1,776.93

/ea as Configured

Weight: 12 lbs
SKU: 99:CBL-Series
Product Name: CBL Series Universal Central Battery System Universal Central Battery System

DESCRIPTION


CONSTRUCTION & OPERATION

  • Supplies emergency power at 24VDC for 90 minutes to any combination of general lighting luminaires fitted with the Series ELC Emergency Lighting Control, MOONLITE LED emergency lighting fixtures, and exit signs.
  • Up to eight 24V emergency branch circuits with wire size from #18AWG to #8AWG can be installed with 1-hour rated metal jacket type "MC” cable, per NEC 700.9 (d)(1). If required, loads may be rated for Class 2 wiring. Hard conduit Class 1 wiring is not required unless specified by local codes.
  • 120 VAC standard input, optional 277, 347 or 480 VAC.
  • NEMA Type 1, UL 50 steel cabinet for surface or optional recess mount.
  • Four CBL models are offered to supply from 100 to 1,000 watts emergency power. Less than 25 watts power consumption in standby mode.
  • Batteries are readily accessible for inspection and maintenance by facilities personnel, allowing timely replacement when indicated by the diagnostic system.
  • 100 or more emergency lighting fixtures and exit signs may be connected to a single central battery panel.
  • Optional installed printer will produce test reports on demand as required by NFPA 101, Paragraph 7.9.3.1.3 (5).

ELECTRONICS

  • Computer-based, self-test/self-diagnostic functions complywith NFPA Life Safety Code 101 (2012) Paragraph 7.9.3.1.3.
  • Automatic self-testing diagnostics is standard, with multicolor LED status display
  • Optional LCD display with diagnostic control center enables RT Clock to set start time for diagnostic testing as required, to avoid test activation of emergency lighting in dark areas or in sensitive areas when building is occupied. Displays show fault reports, battery charge, voltage and current load, battery temperature, and complete fault history.
  • Optional installed printer enables easy compliance with LSC 101 Paragraph 7.9.3 for written reports. Any LCD display can be printed as required.
  • Optional Branch Circuit Load Monitoring automatically reports current flow on 8 individual branch circuits, reducing troubleshooting of possible locations following a fault report (requires LCD option for display).
  • Standard 24V charging system is computer controlled and optimizes current flow for maximum battery life. Optional fast charger recycles system from complete discharge to full capacity in less than 12 hrs.

CERTIFICATION & CODES

  • Listed under UL Standard 924, and meets applicable requirements of CSA C22.2 No. 141, NFPA 101 Para 7.9.3.1.3, and NEC 700.12 (c).

WARRANTY

  • 3 year total customer satisfaction warranty. For details see product catalog technical data section.

This item can replace: CBLSeries

VARIATIONS

CBL 1000-120 CBL 1000-120
  • Wattage: 1000 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 1000-120-FEMA CBL 1000-120-FEMA
  • Wattage: 1000 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: Yes
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 1000-120-S(1000) CBL 1000-120-S(1000)
  • Wattage: 1000 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: Yes 1000 Watts
CBL 1000-120-S(600) CBL 1000-120-S(600)
  • Wattage: 1000 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: Yes 600 Watts
CBL 100-120 CBL 100-120
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-ASA CBL 100-120-ASA
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: Yes
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-BCM CBL 100-120-BCM
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: Yes
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-BH CBL 100-120-BH
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: Yes
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-BMI CBL 100-120-BMI
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: Yes
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-CHG CBL 100-120-CHG
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: Yes
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-CVL CBL 100-120-CVL
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: Yes
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-ECR1 CBL 100-120-ECR1
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: 1 Relay
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-ECR2 CBL 100-120-ECR2
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: 2 Relays
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-ECR3 CBL 100-120-ECR3
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: 3 Relays
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-ECR4 CBL 100-120-ECR4
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: 4 Relays
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-ECR5 CBL 100-120-ECR5
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: 5 Relays
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-ECR6 CBL 100-120-ECR6
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: 6 Relays
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-FAI CBL 100-120-FAI
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: Yes
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-GEN120 CBL 100-120-GEN120
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: 120 VAC
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-GEN277 CBL 100-120-GEN277
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: 277 VAC
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-LCD CBL 100-120-LCD
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: Yes
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-LCM3 CBL 100-120-LCM3
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 3 Inputs
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-LCM4 CBL 100-120-LCM4
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 4 Inputs
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-LOK CBL 100-120-LOK
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: Yes
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-NAT CBL 100-120-NAT
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: Yes
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-NEM4 CBL 100-120-NEM4
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: Yes
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120PRT CBL 100-120PRT
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: Yes
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-RT CBL 100-120-RT
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: Yes
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-S(75) CBL 100-120-S(75)
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: Yes 75 Watts
CBL 100-120-T CBL 100-120-T
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: Yes
  • 24VDC Security Lighting Power Supply: No
CBL 100-120-TD CBL 100-120-TD
  • Wattage: 100 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: Yes
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-277 CBL 100-277
  • Wattage: 100 Watt
  • AC Input Voltage: 277 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-347 CBL 100-347
  • Wattage: 100 Watt
  • AC Input Voltage: 347 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 100-480 CBL 100-480
  • Wattage: 100 Watt
  • AC Input Voltage: 480 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 250-120 CBL 250-120
  • Wattage: 250 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 250-120-S(150) CBL 250-120-S(150)
  • Wattage: 250 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: Yes 150 Watts
CBL 500-120 CBL 500-120
  • Wattage: 500 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: No
CBL 500-120-S(350) CBL 500-120-S(350)
  • Wattage: 500 Watt
  • AC Input Voltage: 120 Volt
  • Active Shooter Alert: No
  • Branch Circuit Load Monitor: No
  • Display Screen: No
  • Building Management Interface: No
  • Fast Battery charge: No
  • Key Lock for enclosure door: No
  • No Annual Auto Test: No
  • Installed Test Report Printer: No
  • Fire Alarm Interface: No
  • Coverlite Door Operation: No
  • Emergency Control Relays: No
  • Extra LCM Signal Inputs: 2 Default
  • FEMA Fan Operation: No
  • NEMA 4X rated Weatherproof enclosure: No
  • Generator Input: No
  • Remote Test Panel: No
  • Time Delay: No
  • Battery Heater: No
  • Time Clock: No
  • 24VDC Security Lighting Power Supply: Yes 350 Watts