Synchron DLS Series Inverter
Brand: Dual-Lite | Hubbell
See PRODUCT DESCRIPTION below
Starting at $5,262.14
PRODUCT VARIATIONS
DESCRIPTION
Single-phase central lighting inverter
- Uninterruptible emergency AC power system
- No break" design transfers the load instantaneously when normal power is interrupted
- 90 minute emergency operation
- Single-phase
- Input/Output Voltage: 120VAC, 277VAC
- 60 Hz operation
- Sizes available from 400 VA/Watts to 2100 VA/Watts
- AC-output breaker standard on 400 and 525VA models
- For normally-on and normally-off loads
- For switched loads using ATSD 20 transfer switches
- 100% load compatible with any lighting source, including HID
- Off line design for high efficiency up to 98%
- Microprocessor controlled pulse width modulation (PWM) using IGBT technology
- Three LED status indicators and an audible alarm provide inverter operating mode status
- Overload and short-circuit protection
- Maintenance-free lead-calcium batteries
- Push button test switch
- Optional: Output circuit breakers in 750 through 2100 VA/Watts models
- Optional: Monitored or unmonitored output circuit breaker supervision
- Optional: Monitoring Program (MP)
- Optional: Preventive Maintenance Program (PMP)
- Optional: Additional Training Visit (ATV)
VARIATIONS
DLS-1000-120-A-15-01
- Model: 1000 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-1000-120-A-15-02
- Model: 1000 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-1000-120-A-20-01
- Model: 1000 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-1000-120-A-20-10
- Model: 1000 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 10 Single Pole
- Output Breaker Supervision: Monitored
DLS-1000-120-A-30-01
- Model: 1000 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 30 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-1000-277-B-15-01
- Model: 1000 VA/Watts
- Input/Output Voltage: 277 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 277 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-1500-120-A-15-01
- Model: 1500 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-1500-120-A-15-02
- Model: 1500 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-1500-120-A-20-02
- Model: 1500 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-1500-120-N-A-15-02-U
- Model: 1500 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-Off
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-1500-120-N-A-15-03-U
- Model: 1500 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-Off
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 3 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-2100-120-A-15-02
- Model: 2100 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-2100-120-A-15-02-U
- Model: 2100 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-2100-120-A-15-03-U
- Model: 2100 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 3 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-2100-120-A-20-06
- Model: 2100 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 6 Single Pole
- Output Breaker Supervision: Monitored
DLS-2100-120-A-20-10
- Model: 2100 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 10 Single Pole
- Output Breaker Supervision: Monitored
DLS-2100-120-N-A-20-02-U
- Model: 2100 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-Off
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-2100-277-B-20-01
- Model: 2100 VA/Watts
- Input/Output Voltage: 277 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 277 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-2100-277-B-20-02
- Model: 2100 VA/Watts
- Input/Output Voltage: 277 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 277 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-2100-277-B-20-06
- Model: 2100 VA/Watts
- Input/Output Voltage: 277 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 277 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 6 Single Pole
- Output Breaker Supervision: Monitored
DLS-2100-277-B-20-10
- Model: 2100 VA/Watts
- Input/Output Voltage: 277 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 277 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 10 Single Pole
- Output Breaker Supervision: Monitored
DLS-2100-277-N-B-15-01-U
- Model: 2100 VA/Watts
- Input/Output Voltage: 277 Volt AC
- Output Circuit Breaker Type: Normally-Off
- Output Breaker Voltage Rating: 277 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-2100-277-N-B-20-02
- Model: 2100 VA/Watts
- Input/Output Voltage: 277 Volt AC
- Output Circuit Breaker Type: Normally-Off
- Output Breaker Voltage Rating: 277 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-400-120-A-15-01
- Model: 400 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-400-120-A-15-01-U
- Model: 400 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-400-120-A-15-02
- Model: 400 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-525-120-A-15-01
- Model: 525 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-525-120-A-15-02
- Model: 525 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-525-120-A-20-01
- Model: 525 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-650-120-A-15-01
- Model: 750 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored
DLS-650-120-A-15-01-U
- Model: 750 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-650-120-A-15-02
- Model: 750 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-650-120-N-A-15-02
- Model: 750 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-Off
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 2 Single Pole
- Output Breaker Supervision: Monitored
DLS-750-120-A-15-04-U
- Model: 750 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 15 Amp
- Output Breaker Quantity: 4 Single Pole
- Output Breaker Supervision: Unmonitored
DLS-750-120-A-20-01
- Model: 750 VA/Watts
- Input/Output Voltage: 120 Volt AC
- Output Circuit Breaker Type: Normally-On
- Output Breaker Voltage Rating: 120 Volt AC
- Output Breaker Ampere Rating: 20 Amp
- Output Breaker Quantity: 1 Single Pole
- Output Breaker Supervision: Monitored